We recreated this in our lab using an onboard LSI SAS 3008 HBA. I was reading that LSI to LSI is supposed to work. ![]() ![]() When I try, I can see the drive in the LSI utility, but it doesn’t immediately register for me to pass-through like others. I’m trying to migrate my old VM store SSD to a ZoL on server. “STH I found info on my LSI 9271-8i and LSI 9300-8i here. The Foreign Drive ProblemĪlthough this question has been asked many times to date, here is the latest question: That is causing the drive to be labeled as foreign. What is happening is that the drive was previously inserted on another machine and a LSI/ Avago configuration was previously written on it. For years now this question has come up in various forms so today it is time to show the easy fix. Avago megaraid storage manager not logging in how to#The process to Update Avago LSI SMIS Provider VMware ESXi is very simple and allows you to stay on top of the latest and greatest bug and stability fixes coming from Avago/LSI.Here is one from the mailbag about how to fix a drive labeled as foreign by a LSI/ Avago SAS controller when it is inserted into a system. This is certainly handy as you can perform many operations using this approach that could only be done otherwise booted into the RAID webui or BIOS screens which would require a maintenance period. As mentioned it allows for remotely monitoring the Avago/LSI disk system, controller, etc, as well as allows us to perform and initiate many operations while the server is up and running in VMware ESXi. If you use the Avago/LSI RAID controllers in any VMware ESXi servers, having the SMIS provider installed is a must have if you ask me. Reboot – either by right-clicking the host in vCenter, issuing the reboot command from an SSH session, or by logging into the console and using the F12 command.Īfter the host reboots, we should be able to use the Avago Storage Manager utility to connect up to our ESXi server on which we updated the SMIS provider. Avago megaraid storage manager not logging in software#This is a good sanity check to make sure it thinks the files have been updated.Īfter the SMIS provider software has been updated, the final step that we need to do is reboot the host. Also, the updater shows the version that is removed and also the version that was installed. Avago megaraid storage manager not logging in update#As you can see below, the version I currently had installed was version 500.04.V0.56-0005.Īs you see below, you should see the update completed successfully after a few moments. When we run the command we should see the lsiprovider listed. To do that we can use the esxcli command: esxcli software vib list The first thing for posterity sake that I wanted to do was see which version of the SMIS provider I had installed already. Avago megaraid storage manager not logging in drivers#However, the SMIS provider and drivers still have the LSI branding aside from the “Avago” Storage Manager. Update Avago LSI SMIS Provider VMware ESXiīefore we begin, LSI was bought by Avago Tech which is owned by Broadcom (are you keeping it straight?) so we will use the terms interchangeably. If you have already installed the SMIS provider, how do we update? Let’s look at how to Update Avago LSI SMIS Provider VMware ESXi. The powerful part of using the remote utility is that all of this can be done while the system is booted into VMware ESXi. This is also extremely handy if you need to check the status of a drive rebuild or silence the error “beep” during a drive rebuild. If you are running an Avago/LSI RAID controller card in a VMware host, Avago has an SMIS provider that can be installed on the host that allows you to connect a remote Storage Manager utility to the server and interact remotely with the RAID controller and even perform or initiate RAID controller operations.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |